hayward flow switch troubleshooting

Hayward Flow Control has been a leading manufacturer of industrial thermoplastic valves and process control products for more than 60 years. Check that the flow line is plugged all the way into the control box.


Hayward Aqua Rite Troubleshooting Guide Poolsupplyworld Blog

Check for damaged or cut wire.

. Step 2 Ensure the flow switch valve is open. Wait for the relay to click 5 to 10 seconds. Then give Hayward a call at 866-772-2100 to see what they say.

If there is adequate flow and the LED is still on check that the arrows on the flow switch on top of hex are pointing in the direction of flow. Gas valve opens and monitors flame sense. After three attempts to use a cheaper product ordered the Hayward flow switch and glad I did.

Right click on the link of the file you wish to download. First two failed after exactly three days. To reset move the switch to Off and then back to Auto.

GLX-FLO-RP Flow switch is factory original The GLX-FLO-RP screw into your existing tee and comes with a 15 cord. Hayward websites have been developed in compliance with standards for Internet Explorer 10 or later. Page 8 If LED is flashing wait 60 seconds after starting filter pump.

To view these documents you will need to download the free Acrobat Reader. Then check for possible turbulence inside the flow T. If LED is ON check for flow switch installed backward.

Flow Switch Assembly GLX-FLO-RP for HaywardGoldline Aquarite Salt Systems Pool Flow Sensor Suitable for Hayward Salt Cell and Salt Chlorine Generator System with 15-Foot Cable. The Hayward switch it replaced lasted 5 years on my saltwater pool. Verify the flow switch has 12 of straight pipe before it.

Flow switch requires a minimum flow rate of Il gpm to stay closed consistently. Third one didnt work at all. In fact Hayward was one of the originators of the first thermoplastic ball valves.

Salt Chlorine Generators Parts Diagram. If the flow switch is installed too close to an outletbend re-plumb the switch to a location where it will not experience as much turbulence. You can test the continuity of the flow switch using a Voltmeter or Ohmmeter.

If you dont have access to a VOM then perhaps the below might help. HCP 300 Series. You can use the two wire tel cord if available.

No more mixing measuring and messing around with liquid or tablet chlorine again. IE9 and older versions are not supported. That test bypasses tests for low flow and arrows installed wrong.

Plug the cable back in and check the valve again. USB drive must already be connected to your computer. Page 8 If LED is flashing wait 60 seconds after starting filter pump.

AquaRite Hayward Goldline Aqua Rite Salt Generator FLO Flow Switch GLX-FLO-RP. At proper Igniter temp a 4 second trial begins. If it is not open disconnect the cable and wait for six seconds.

Hayward AqauRite Parts - httpbitly38uhdcpTeflon Tape - httpbitly38tErzwTroubleshooting Your Hayward Aqua Rite System - httpbitly2TMYlkRThe Flo. Darrin - If you held the switch contacts closed for 60 seconds and the No Flow LED did not go off your new switch may be bad. Pump only Runs for 5 seconds If your Hayward pump runs for only.

Arrows at the top of the hex nut need to point in the direction of water flow. This generic replacement for the Hayward Goldline flow switch is relatively. Alternatively continuity is close if sufficient water flow is detected.

Ensure the flow switch valve is open. While you are checking the valve position check the valve to make sure there are no obstructions. Within the options menu select Save link as Note.

The plumbing installation requires 12 inches of straight pipe before the flow switch. Switch-FlowReplacementNo Tee Item GLX-FLO-RP. It takes about 30 seconds for the unit to settle back on the default reading.

When the instant salt level is stable and the negative sign still present slide switch to Super Chlorinate and back to Auto. From the Save As window. Flow switch requires a minimum flow rate of Il gpm to stay closed consistently.

The Control checks for a closed Blower Vacuum Switch. There should be no elbow pipe after the flow switch. Blower starts pre-purge cycle as the igniter heats up 20 Sec.

The control checks for open Blower Vacuum Switch 2. If flashing wait about 60 seconds after starting the pool pump. If anything is stuck in the valve holding it open the unit will not work properly.

Continuity is open if there is no flow. Check for possible turbulence inside of flow T. Installation requires 12 inches of straight pipe before flow switch.

Check that the flow switch is plugged into the connector on the bottom of the control unit and that the wire is not cut or damaged. Learn more about Salt Chlorination. Direction of water flow.

Check the wire for any damage. No Flow LED is flashing or ON. The blower will turn off for one second.

No more mixing measuring and messing around with liquid or tablet chlorine again. Step 1 Power LED not on. Since then we have remained committed to producing the highest quality products while providing outstanding service.

This one is chugging right along. 45 out of 5 stars. Check for damaged or cut wire.

If you have questions regarding troubleshooting a problem installing this flow switch call 1-888-921-7665 for Technical support. Rotate the flow switch until the raised surface on the hexagonal nut is.


How To Troubleshoot A Hayward Aqua Rite Inyopools Com


Hayward Goldline Replacement Flow Switch Glx Flo Rp


Heatpump Troubleshooting Manualzz


How To Recalibrate A Hayward Aqua Rite Turbo Cell Poolsupplyworld Blog


How To Replace A Hayward Aqua Rite Flow Switch Chlorine King Pool Service Youtube


Hayward Flow Switch Glx Flo Rp Pool Supply 4 Less


How To Replace An Aqua Rite Flow Switch Youtube


Hayward Aquarite Salt System No Flow Tips And Tricks To Easily Diagnose And Fix Youtube


One Minute Fix No Flow On Aqua Rite Hayward Salt Generator Youtube


How To Diagnose And Repair Your Hayward H Series Natural Gas Swimming Pool Heater Youtube


Hayward Aqua Rite Troubleshooting Guide Poolsupplyworld Blog


Hayward Aqua Rite Troubleshooting Guide Poolsupplyworld Blog


Hayward Aqua Rite Troubleshooting Guide Poolsupplyworld Blog


Hayward Aquarite Swg Further Reading Trouble Free Pool


Hayward Goldline Replacement Flow Switch Glx Flo Rp


New Pool Owner Salt System Keeps Reporting No Flow My Salt Cell Isn T Generating Chlorine I Cleaned The Cell Changed The Flow Switch Decreased And Increased The Pressure From The Return I


Hayward Aqua Rite Troubleshooting Guide Poolsupplyworld Blog


Hayward Aqua Rite Troubleshooting Guide Poolsupplyworld Blog


Hayward Flow Switch Glx Flo Rp Pool Supply 4 Less